Hioki ST5540 Medidor de corriente de fuga

Descripción
Medidor de corriente de fuga de banco con rango de 50mA en AC/DC con precisión de ±2%, puede medir un voltaje de hasta 240V en AC, medición de rigidez dieléctrica de hasta 2.30kV en AC; tipos de comunicación: USB, RS232, entrada / salida externa; display LCD este modelo cuenta con modos de mediciones médicas. Modelo Hioki ST5540

código: ST5540

Description

Características
Medidor de corriente de fuga – Hioki ST5540
  •  » IEC 60601-1: (2005) 3rd Edition, JIS T0601-1:2012 compliant
  •  » The ST5540 complies with JIS, IEC, and UL standards governing medical- and general-use electrical devices.
  •  » Uninterrupted polarity switching function dramatically reduces cycle time.
  •  » Support for rated currents up to 20 A gives the instrument more than adequate capability for testing products designed to comply with new standards.
  •  » Touch panel features simple, interactive operation.
  •  » Communications functionality and external I/O support allow automatic testing on production lines.
  •  » Measurement methods: Measurement of voltage drop across body simulated resistance points. Calculation and display of current values True rms measurement. Measurement unit floats relative to instrument ground.
  •  » Measurement modes: Leak current measurement, voltage measurement, safety conductor current measurement
  •  » Standard compliance: Medical electrical equipment: IEC 60601-1 (1988) + A2:1995, (2005, 3rd Edition), JIS T0601-1:1999, 2012; Electrical Appliances and Materials Safety Act; Measurement of touch current and protective conductor current: IEC 60990 (1999); Electrical equipment for measurement, control, and laboratory use: IEC 61010-1 (2001); Information technology equipment: IEC 60950-1 (2005); Household and similar appliances: IEC 60335-1 (2001) + A1:2004 + A2:2006; Audio, video and similar electronic apparatus: IEC 60065 (2001) + A1:2005; Personnel Protection Systems for EV: UL-2231-1 (2002), UL-2231-2 (2002); UL: UL-1492 (1996); Electrical equipment for measurement, control, and laboratory use; current measurement circuits in damp conditions: IEC 61010-1 (2001)
  •  » Leak current measurement: Ground leak current, 3 types of contact current, 7 types of patient leak current, patient measurement current, 4 types of total patient leak current, free current measurement, 3 types of enclosure leak current
  •  » Measurement current: DC, AC (true rms, 0.1 Hz to 1 MHz), AC+DC (true rms, 0.1 Hz to 1 MHz), AC peak (15 Hz to 1 MHz)
  •  » Measurement ranges: DC / AC / AC+DC mode:50 µA/500 µA/5 mA/50mA AC peak mode:500 µA/1 mA/10 mA/75 mA
  •  » Measurement accuracy (current measurement)
  •  » DC measurement: ±2.0% rdg. ±6 dgt. (typ.): AC / AC+DC measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 100 kHz, typ.); AC peak measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 10 kHz, typ.)
  •  » Interfaces: External I/O, medical device relay output, USB 1.1 (communications), RS-232C
  •  » Functionality: 110% voltage application, automatic test, data storage for 100 target devices, clock, data backup, printed output (optional), etc.
  •  » HiTESTER power supply: 100/120/220/240 V AC (specify at time of order), 50/60 Hz, 30 VA rated power
  •  » Target device power supply input: 100 to 240 V AC, 50/60 Hz Rated current input from terminal block: 20 A
  •  » Target device power supply output: Output from terminal block: 20 A Output from outlet: 15 A
Qué Incluye:
  •   TEST LEAD L2200 (for ST5540, Red × 2, Black × 1) × 1 set
  •   ENCLOSURE PROBE 9195 × 1
  •   Power cord × 3
  •   Spare fuse for measurement line × 1
  •   Instruction manual × 1
  •   Users guide × 1
  •   CD-ROM × 1

Reviews

There are no reviews yet.

Be the first to review “Hioki ST5540 Medidor de corriente de fuga”

Your email address will not be published. Required fields are marked *

Title