Hioki CT6862 Transformador de Corriente 50A AC/DC. ⌀24mm, conector BNC

Descripción

Transformador de corriente hasta 50A AC/DC, ⌀24mm de diámetro, precisión del 0.05%, conector BNC; longitud del cable de conexión: 3m, ancho de banda 1 MHz

código: CT6862

Description

Características
Transformador de Corriente 50A AC/DC. ⌀24mm, conector BNC – Hioki CT6862
  •  Wide-Bandwidth and High-Precision Current Measurement Possible
  • Super high precision, ±0.06% amplitude accuracy, ±0.2 degree phase accuracy
  • Wide-bandwidth DC to 1 MHz (CT6862) excellent frequency characteristics
  • Applications in the fields of electric and hybrid electric vehicles
  • A wide operating temperature range is fit to the automobile measurement
  • Applications in generating electricity by the sun light, a battery charge and discharge measurement and inverter secondary circuit measurement
  • For observing waveforms to be used with the MEMORY HiCORDERs
  • Rated current 50 A AC/DC
  • Max. allowable input 100 A continuous (requires derating at frequency or temperature)
  • Frequency characteristics Amplitude: DC to 1 MHz Phase: DC to 300 kHz
  • Amplitude and Phase accuracy DC ±0.05 % rdg. ±0.01 % f.s. (Phase: Not be defined), 16 Hz = f = 400 Hz ±0.05 % rdg. ±0.01 % f.s. (Phase: ±0.2 deg), Be defined to 1 MHz
  • Output voltage 2 V/rated current range (voltage output with the Sensor Unit 9555-10, use with a device having a 1 Mohm input resistance or higher)
  • Max. rated voltage to earth AC/DC 1000 V (50/60 Hz, CAT III )
  • Core diameter Φ 24 mm (0.94 in)
  • Power requirements DC ±11 V to ±15 V (Power suppled via the 9555-10, 9555-10 requirement with 100 to 240 V AC)